{"product_id":"trac-submersible-thru-hull-pump-800-1100-gph","title":"Trac Outdoor Aerator Pump 3\/4-1 1\/2\" 800\/1100Gph","description":"\u003cp\u003eTRAC 69321 Submersible Thru-Hull Pump 800\/1100 GPH\u003c\/p\u003e\u003cp\u003eThe TRAC 69321 Submersible Thru-Hull Pump is a self-priming, 12V centrifugal pump that's ideal for all watercraft. Designed for easy installation and retrofitting, this pump features a cartridge style pump head and universal strainer base. This versatile thru-hull pump comes packaged with both a 1-1\/8\" 1100 GPH outlet and a 3\/4\" 800 GPH outlet. Each outlet has an O-ring for easy maneuverability without stripping. The TRAC 69321 Thru-Hull Pump can run dry without damage and is designed to have a low power draw. Additionally, it meets ABYC, Coast Guard, and ISO standards.\u003c\/p\u003e\u003cp\u003eThe universal strainer base in connection-compatible, and is able to fit: Attwood Tsunami, Rule, and Johnson\/Mayfair cartridge pumps. The screw mounting holes match Rule and Attwood Tsunami.\u003c\/p\u003e\u003cp\u003eFeatures:\u003c\/p\u003e\u003cp\u003eCartridge style pump head\u003c\/p\u003e\u003cp\u003ePump body accepts both 3\/4\" \u0026amp; 1-1\/8\" screw-on outlets\u003c\/p\u003e\u003cp\u003eIgnition protected with low power draw\u003c\/p\u003e\u003cp\u003eRuns dry without damage\u003c\/p\u003e\u003cp\u003eMeets ABYC, Coast Guard and ISO marine standards.\u003c\/p\u003e\u003cp\u003e1 year warranty\u003c\/p\u003e\u003cp\u003eSpecifications\u003c\/p\u003e\u003cp\u003e3\/4\" Dia. Outlet = 800 GPH\u003c\/p\u003e\u003cp\u003e1-1\/8\" Dia. Outlet = 1100 GPH\u003c\/p\u003e\u003cp\u003e5 Amp Fuse - 12V DC\u003c\/p\u003e\u003cp\u003e3.7A @ 13.6V DC\u003c\/p\u003e\u003cp\u003eHow to Install TRAC 69321 Thru-Hull Pump\u003c\/p\u003e\u003cp\u003eInstallation\u003c\/p\u003e\u003cp\u003eLocate a spot where you want to drill a hole for installing the pump.\u003c\/p\u003e\u003cp\u003eMake sure the location is below the waterline when the boat is not moving.\u003c\/p\u003e\u003cp\u003eLook both inside and outside the boat at the installation location to make sure there is enough room for the pump and fittings.\u003c\/p\u003e\u003cp\u003eDrill a 1” diameter hole.\u003c\/p\u003e\u003cp\u003ePlace the white rubber gasket on the threaded fitting and slide the threaded fitting through the hole.\u003c\/p\u003e\u003cp\u003eThe pump should be on the inside of the boat and the white rubber gasket should be between the pump and the boat.\u003c\/p\u003e\u003cp\u003eApply pipe tape to the threads then screw the nut on and hand tighten.\u003c\/p\u003e\u003cp\u003ePoint the pump output nozzle up. Tighten the nut on the fitting on the outside of the boat.\u003c\/p\u003e\u003cp\u003eThe nut should be tight enough to seal, but do not over tighten.\u003c\/p\u003e\u003cp\u003eA marine-grade silicon sealant can be used to seal the hole that is drilled and to seal around the nut.\u003c\/p\u003e\u003cp\u003eUse a saw to remove the excess length of the threaded fitting.\u003c\/p\u003e\u003cp\u003ePush the strainer screen into the end of the fitting on the outside of the boat.\u003c\/p\u003e\u003cp\u003eUse 16 gauge or heavier marine wire.\u003c\/p\u003e\u003cp\u003eConnect the brown wire to a suitable switch.\u003c\/p\u003e\u003cp\u003eConnect the switch to fuse. Use the proper size fuse and fuse holder.\u003c\/p\u003e\u003cp\u003eSee pump head for recommended fuse rating.\u003c\/p\u003e\u003cp\u003eConnect the fuse to the positive (+) side of the battery.\u003c\/p\u003e\u003cp\u003eConnect the black wire to the negative (-) side of the battery.\u003c\/p\u003e\u003cp\u003eConnect a suitable hose to the thru-hull pump. Use a clamp to secure the hose to the pump. Make sure that the hose runs uphill, or rises, to the control valve on the livewell.\u003c\/p\u003e\u003cp\u003eConnect the hose to the control valve and secure with a clamp.\u003c\/p\u003e\u003cp\u003eKeep all wire connections above highest possible water level. Seal all wire connections and ends with liquid electrical tape or heat shrink splices to prevent corrosion.\u003c\/p\u003e\u003cp\u003eThe pump is located below the water line. Water can enter the boat if the clamps are not tightened properly.\u003c\/p\u003e\u003cp\u003eOperation\u003c\/p\u003e\u003cp\u003eThe boat must be at rest to fill the livewell.\u003c\/p\u003e\u003cp\u003eTurn the pump on and open the control valve on the livewell.\u003c\/p\u003e\u003cp\u003eThe livewell will fill until the water runs out of the overflow pipe.\u003c\/p\u003e\u003cp\u003eThe pump can be left running for a continuous flow of fresh water.\u003c\/p\u003e\u003cp\u003eThe livewell control calve must be closed when pump is not running.\u003c\/p\u003e\u003cp\u003eInformation sourced from the TRAC Thru-Hull Pumps Installation and Operation Instructions.\u003c\/p\u003e\u003cp\u003eClick Here to Download TRAC Thru Hull Pump User Manual\u003c\/p\u003e","brand":"Trac Outdoor","offers":[{"title":"Default Title","offer_id":50584348098818,"sku":"TRC-69321","price":57.99,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0842\/3024\/2562\/files\/69321__48877.1739460369_ed006a71-c427-4d76-8fde-41c90d7a67ed.jpg?v=1791101836","url":"https:\/\/allmarineworld.com\/products\/trac-submersible-thru-hull-pump-800-1100-gph","provider":"All Marine World","version":"1.0","type":"link"}